Evaluation of the quality of the air for the oxides of nitrogen, municipality Santo Domingo, county Villa Clara, Cuba

Main Article Content

Vladimir Núñez-Caraballo
Guillermo Saura-González
Rosabel Rodríguez-Rojas
Meilyn Otero-Martín
Amaury Machado-Montes de Oca
Marisela Purón-Arbolaez
Inocencio Martínez-Pérez
Luis E. Pérez-Borroto
Osvaldo Cuesta-Santos
Idalberto Herrera-Moya
Mayra C. Morales-Pérez
Julio Pedraza-Gárciga
Daniellys Alejo-Sánchez

Abstract

The present work manifests the evaluation of the quality of the air for the Oxides of Nitrogen (NOX) starting from the emissions of the inventory of the 45 fixed sources and the self-driven flow for the main road, in the municipality of Sacred Domingo, county of Villa Clara, in the year 2017. The general objective was to evaluate the quality of the air for the NOx starting from the emissions to the atmosphere taken place by these sources. The calculation method was used based on the emission factor to determine the rate of the pollutants of both sources and the modulation of the dispersion of the pollutant to evaluate the quality of the air. The main results were, 82% of the fixed sources is well located and they emitted 7% of the total, 18% is partially well located and they expelled 91% and the mobile sources emitted 2%. The areas with deterioration of the quality of the air in Sacred Domingo's city the around went to the main road for where the self-driven transport circulated, reaching a category of Faulty in 24 hours and Bad in one hour (bigger vehicular flow). The emissions of the fixed sources partially well located they can influence in the quality of the air on the population establishments outside of the city, in near areas to their origins.

Downloads

Download data is not yet available.

Article Details

How to Cite
Núñez-CaraballoV., Saura-GonzálezG., Rodríguez-RojasR., Otero-MartínM., Machado-Montes de OcaA., Purón-ArbolaezM., Martínez-PérezI., Pérez-BorrotoL. E., Cuesta-SantosO., Herrera-MoyaI., Morales-PérezM. C., Pedraza-GárcigaJ., & Alejo-SánchezD. (2018). Evaluation of the quality of the air for the oxides of nitrogen, municipality Santo Domingo, county Villa Clara, Cuba. Revista Cubana De Meteorología, 24, 365-373. Retrieved from http://rcm.insmet.cu/index.php/rcm/article/view/442
Section
Original Articles

References

Aguilar, J. A. et al. (2007). Guía metodológica para la estimación de emisiones vehiculares en ciudades mexicanas. Secretaría de Medio Ambiente y Recursos Naturales. Instituto Nacional de Ecología. Western Governors Association.
Cabrera, F. et al. (2007). Evaluation of a dispersion model in Tula's industrial complex in Mexico by optical remote sensing methods. The Smithsonian/NASA Astrophysics Data System. American Geophysical Union, Spring Meeting.
Carrillo, E. et al. (2012). Evaluación de la calidad del aire, en la ciudad de Pinar del Río utilizando el modelo DISPER 4.0. Convención Trópico 14-18 Mayo, 2012, La Habana Cuba, ISBN: 978-959'282-079-1.
DAMA - INAMCO (2001). Elaborar un Inventario de fuentes fijas de emisión de contaminantes a la atmósfera en la ciudad de Bogotá. Informe final del contrato 079/2000, Santa Fe de Bogotá.
DICTUC S.A. (2007). Actualización del Inventario de Emisiones de Contaminantes Atmosféricos en la Región Metropolitana 2005. Santiago de Chile.
Cuesta, O. et al. (2003). Calidad del aire en la zona de la ribera este de la bahía de La Habana. Memorias publicadas en el Congreso Iberoamericano de Meteorología, 2003. La Habana. ISSN 959-270-014-1.
Cuesta, O. et al. (2014). Diagnóstico del medio ambiente atmosférico producto de las principales fuentes fijas de la Ciudad de La Habana. Proyecto de Innovación Tecnológica. CECONT, Instituto de Meteorología, La Habana, Cuba.
EMEP/CORINAIR (2007). Guía para la realización del inventario de emisiones atmosféricas de la Agencia Europea de Medioambiente.
EPA. (1995a). Compilation of air pollutant emission factors. Emission factor documentation for Stationary Internal Combustion Sources. AP-42, Section 3.0.1.
EPA. (1995b). Compilation of air pollutant emission factors. Emission factor documentation for Portland Cement Manufacturing. AP-42, Section 11.6.1.
EPA. (1995c). Compilation of air pollutant emission factors. Emission factor documentation for Portland Cement Manufacturing. AP-42, Section 11.6.2.
Huertas, J. et al. (2010). Modeling Dispersion of PM10 and PST in the Cesar Department Mining Region, Colombia by Using ISC and AERMOD. ASME 2010 Power Conference (POWER2010), Paper no. 27356, pp.97-112. ISBN: 978-0-7918-4935-4.
INEM (2014). Elaboración del inventario nacional de emisiones de fuentes móviles para México 2013 y proyección 2030 mediante el modelo Motor VehicleEmission Simulator (MOVES). Informe técnico final. Instituto Nacional de Ecología y Cambio Climático.
López, C. (2007). Introducción a la Gestión de la Calidad del Aire. Instituto de Meteorología. Centro de Contaminación y Química Atmosférica. La Habana.
Martínez, E. et al. (2004).Contaminación atmosférica. Colección Ciencia y Técnica 45, Universidad de Castilla-La Mancha, ISBN 84-8427-324-5, pp.13-30, 385-402.
NC 111: 2004. Calidad del Aire-reglas para la Vigilancia de la calidad del Aire en Asentamientos Humanos. Norma Cubana. Oficina Nacional de Normalización (ONN). Cuban National Bureau of Standards.
NC 1020:2014. Calidad del Aire-Contaminantes-Concentraciones Máximas Admisibles y Valores Guías en zonas Habitables.Oficina Nacional de Normalización (ONN). Cuban National Bureau of Standards.
NC 1049: 2014. Guía de datos tecnológicos para el inventario de emisiones de los contaminantes atmosféricos desde fuentes industriales estacionarias.Oficina Nacional de Normalización (ONN). Cuban National Bureau of Standards.
Núñez, V. et al. (2008). Predicción y Control de episodios críticos de contaminación atmosférica de PM10 producida por fuentes fijas a través de la modelación como método de gestión de la calidad del aire en asentamientos poblacionales. Convención Trópico, 16-20 Junio, 2008, La Habana, Cuba, ISBN: 978-959-282-079-1.
Núñez V. et al. (2009). Propuestas, evaluación y aplicación del control de las emisiones de PM10 en fundición de acero para prevenir episodios críticos de contaminación atmosférica. 5to. Congreso Cubano de Meteorología, 1-4 Diciembre, 2009, La Habana, Cuba, ISBN: 978-959-7167-20-4.
Núñez V. et al. (2010). Pronósticos de calidad del aire para diferentes escenarios de emisión de fuentes fijas como método de control y reducción de las emisiones de PM10 . 4to. Simposio internacional de Química, 1-4 Junio, 2010, UCLV, Villa Clara, Cuba. ISBN: 978-959-7167-12-9.
Núñez V. et al. (2011). Fuentes fijas responsables de las máximas emisiones de SO2 en la provincia de Villa Clara, Cuba, en el primer semestre 2011. 6to. Congreso Cubano de Meteorología. La Habana, Cuba, ISBN: 978-959-7167-23-2.
Núñez V. et al. (2013). Carga contaminante emitida a la atmósfera por las fuentes fijas principales en la provincia de Villa Clara. Revista Centro Azúcar. No 2 del 2013. ISSN:2223-4861.
Núñez V. et al. (2014). Emisiones a la atmósfera de material particulado de centrales azucareros y refinerías de azúcar en la provincia de Villa Clara. Cuba. Revista ICIDCA.Vol. 48 No. 2 de 2014.
Núñez, V. (2015). Metodología de diagnóstico técnico ambiental en fuentes fijas industriales para prevenir y mitigar los Episodios Críticos de Contaminación Atmosférica y el impacto a la salud humana.Tesis en opción al grado de Doctor en Ciencias Técnicas. Facultad de Química y Farmacia. Departamento de Ingeniería Química. Universidad Central “Marta Abreu” de Las Villas. Cuba.
Sánchez, P. et al. (2007). Calidad del aire y condiciones meteorológicas como factores de riesgo para la salud en una zona urbana de la Ciudad de la Habana. 4to. Congreso Cubano de Meteorología, 4-8 Diciembre, 2007, La Habana, Cuba. ISBN: 978-959-7167-12-9.
SEMARNAT (2013). Calidad del aire: una práctica de vida. Cuadernos de divulgación ambiental. Primera edición 2013. 28 p.
Toro, M. V. et al. (2010). Simulaciones especiales tarea 1. Actualización del inventario de emisiones atmosféricas. Informe Final. Universidad Pontificia Bolivariana.
WHO (2005). Air Quality guidelines global update. Bonn, Germany.

Most read articles by the same author(s)